Most heat recovery units are designed to stand on a floor or hang off a wall in a plant cupboard. In an apartment that cupboard often does not exist. The DucoBox Energy Sky D275 solves that by going flat against a ceiling or wall instead.
The numbers
275 m³/h (76 l/s) at 200 Pa, four Ø160 mm duct connections, 670 x 1180 x 295 mm, 19 kg. The important figure is 295 mm: shallow enough to disappear into a suspended ceiling or a hallway bulkhead.
Where it beats a Comfort or Premium unit
The Energy Comfort and Comfort Plus units and the Energy Premium range are the right answer in a house with a utility room or loft. In a flat or a conversion with no spare floor area, the Sky is often the only unit that fits without taking a cupboard off the occupier.
Demand control and zoning
The Sky works with Duco's sensor range, so ventilation follows occupancy rather than a timer. Add CO2 and humidity sensors and the unit modulates itself. For a two-zone flat, the Multizone D160 basic kit adds zone valves so bedrooms and living space are treated separately.
Filters and access
Access matters more on a ceiling unit, because every filter change happens up a ladder. Plan the hatch before the plasterboard goes up. The Sky takes its own D275 sets: a twin Coarse 65% set for standard use, or a Coarse 65% / ePM1 55% set where pollen or urban particulates matter.
Ducting a ceiling unit
Four 160 mm connections leave the unit, and in a ceiling void the two cold lines still need insulating or condensation will form on the outside of the duct. Use insulated ISO ducting on the outdoor and exhaust air runs and semi-rigid radial duct for distribution to rooms.
A ceiling void also puts the unit directly above a room, so acoustics deserve attention. A duct silencer on the supply and extract trunks is cheap insurance against fan noise telegraphing into a bedroom.
Specifying one
Send us the floor plan, the ceiling void depth and the terminal positions and we will size it. See the MVHR range or call 01283 380031 | sales@pureclima.co.uk.