Duco Manifolds, Adapters and Flow Regulators: From DucoBox to Room

Short answer: the manifold is where the DucoBox's large duct connections fan out into the small radial runs that serve each room. Between the two sit adapters, reducers and branch pieces that change diameter or split a flow, and flow regulators that set how much air each branch actually gets. Get this middle section right and commissioning is straightforward; get it wrong and no amount of adjustment at the valves will fix it.

DucoFlex manifold box for floor and ceiling with four oval air duct connections and Ø160 mm inlet

The manifold: one box, many runs

A radial ventilation system gives every room its own duct. Those runs have to start somewhere, and that somewhere is a manifold box: a plenum with one large connection to the DucoBox and several small ones to the rooms.

PureClima stocks two DucoFlex manifold boxes, both designed for floor or ceiling installation:

That second variant is the useful one in awkward layouts. Rather than running four long ducts back to a single central point, you can place a second manifold nearer a cluster of rooms and feed it from the first.

Getting air up through the building

Where ducts have to rise between floors, the riser duct connector takes a round Ø160 mm duct and splits it into two oval ducts, which fit far more comfortably inside a stud wall or service riser than round duct of equivalent capacity. Oval section is the standard answer to the problem of getting adequate airflow through a shallow void.

Adapters: round duct to oval duct

Where round semi-rigid runs meet oval duct, an adapter makes the joint. The naming tells you exactly what each one does — how many round ducts of which diameter it accepts:

Adapter Accepts
Adapter 3 × 63 oval Three Ø63 mm round ducts
Adapter 2 × 75 oval Two Ø75 mm round ducts
Adapter 3 × 75 oval Three Ø75 mm round ducts
Adapter 2 × 90 oval Two Ø90 mm round ducts

Choosing duct diameter and choosing adapters are therefore the same decision made twice. Our guide to DucoFlex duct sizes covers the first half of it.

At the unit: reducers, breeches and branches

Close to the DucoBox the duct is larger, and three fittings handle the common transitions:

  • The reducer Ø160 / Ø125 steps a Ø160 mm duct down to Ø125 mm, or makes the transition from a DucoBox spigot to the duct size used in the design.
  • The breech Y-piece merges two Ø125 mm spigots into a single Ø160 mm duct — useful where a unit has more connections than the duct route needs.
  • The branch piece Ø180 → 2 × Ø160 splits supply air into two for two-zone control.

That last one pairs with the multi-zone valves: the Ø160 mm sensorless multi-zone valve and its Ø125 mm counterpart, both controlled by the unit rather than by their own sensor, and listed as compatible with DucoBox Energy Comfort (Plus) and Energy Sky. The Ø160 version needs 78 mm of clearance to install, which is worth checking against your plant space before the ceiling closes up.

Flow regulators: setting the balance

A duct network delivers air according to its resistance, not according to your intentions. Short runs get too much, long runs get too little, and commissioning is the process of correcting that. Flow regulators are the fittings that make it possible:

Regulator Flow range Diameter
Flow regulator 15–50 m³/h 15–50 m³/h Ø80 mm
Flow regulator 15–50 m³/h 15–50 m³/h Ø125 mm
Flow regulator 50–100 m³/h 50–100 m³/h Ø125 mm

Pick the regulator whose range brackets the design flow for that branch, with the design figure somewhere in the middle rather than at an extreme. A regulator working at the very bottom of its range is a restriction, and restrictions make noise.

Note that there are two Ø125 mm versions covering different flow bands. They look similar on a parts list, so check the range as well as the diameter when ordering.

A sensible order of decisions

  1. Room flow rates come from the ventilation design.
  2. Duct diameter and run count follow from those rates.
  3. Manifold count and type follow from the number of runs and where they converge.
  4. Adapters follow from the duct diameter and the runs per adapter.
  5. Reducers, breeches and branches follow from the unit's spigot sizes and whether the system is zoned.
  6. Flow regulators are chosen last, by branch flow and duct diameter.

Before you order, confirm

  • How many runs each manifold has to serve, and whether one box is enough
  • Whether you need the linkable 3 + 1 manifold rather than the 4-way
  • The duct diameter, so the adapters match
  • The DucoBox spigot size and count — Ø125, Ø160 or Ø180 depending on model
  • Clearance for multi-zone valves, including the 78 mm needed by the Ø160 version
  • Design flow per branch, against each regulator's range

Frequently asked questions

Do I need flow regulators if the valves are adjustable?

Adjustable valves set the final flow at the room. Regulators work further upstream, on the branch, which is where a large imbalance is better corrected. On a well-designed system you may need few; on a system with very unequal run lengths they do real work.

Can I put a manifold anywhere?

It needs to stay accessible, and the runs leaving it need their bend radius respected from the moment they leave the box. A manifold crammed against a joist with ducts kinked at the outlet undoes much of the benefit of a radial system.

Which DucoBox connection size will I be adapting from?

Ø125 mm on the MEV units, Ø160 mm on most MVHR units and Ø180 mm on the Energy Comfort D400. Our DucoBox range guide lists each one.

What about noise from the manifold?

A manifold close to the unit can transmit fan noise into every run. An in-line silencer between unit and manifold is the usual answer — see Duco silencers compared.

Next step

Manifolds, adapters and transition fittings are in the ducting solutions and ventilation accessories collections. If you have a duct layout but are unsure which fittings it implies, send us the drawing and we will list the parts.