Short answer: DucoFlex semi-rigid radial ducting comes in three diameters — Ø63 mm, Ø75 mm and Ø90 mm, each supplied on a 50 m roll. The diameter you choose sets how much air one run can carry at an acceptable velocity, and therefore how many runs each room needs. Every size has its own matching couplings, O-rings, cutter and manifold adapters, and they are not interchangeable.

What semi-rigid radial ducting is
In a radial system, every room is served by its own continuous duct run from a central manifold, rather than by branches off a shared trunk. Semi-rigid duct is the pipe that makes that practical: stiff enough to hold its shape and resist crushing under a screed or in a joist void, flexible enough to be coiled on a roll and snaked through a building without a fitting at every change of direction.
All three DucoFlex sizes share a smooth, antistatic and antibacterial inner wall. The smooth bore matters more than it sounds: ribbed flexible duct generates turbulence, which costs pressure and makes noise, and its ridges collect dust that is almost impossible to clean out later. A smooth bore keeps the resistance predictable and the duct cleanable.
Because each run is continuous from manifold to room terminal, there are no hidden joints buried in the structure — a significant advantage when a system has to stay airtight for decades.
The three diameters
| Size | Supplied as | Inner wall | Typically used for |
|---|---|---|---|
| Ø63 mm | 50 m roll | Smooth, antistatic and antibacterial | Tight voids and shallow floor build-ups, with more runs per room |
| Ø75 mm | 50 m roll | Smooth, antistatic and antibacterial | The general-purpose size for most dwellings |
| Ø90 mm | 50 m roll | Smooth, antistatic and antibacterial | Higher flow per run, fewer runs, where depth allows |
The trade-off runs in one direction throughout. A smaller duct fits where a larger one will not, but carries less air per run, so a room needing a given flow rate needs more runs — more penetrations, more manifold ports, more labour. A larger duct carries more per run and is quieter at the same flow, but needs more depth in the floor or ceiling.
Do not pick the size by eye. Your ventilation designer calculates each room's supply and extract rate, then sets the number and diameter of runs so that air velocity in the duct stays low enough to be quiet. Running too much air down too small a duct is the single most common cause of an MVHR system that whistles.
Everything else is size-specific
Once the diameter is fixed, the rest of the kit follows it. These parts are matched to one size and will not fit another:
- Couplings join two lengths of duct or connect duct to a fitting: Coupling D63, D75 and D90.
- Rubber O-rings make the seal at every connection, supplied in packs of ten: D63, D75 and D90.
- Duct cutters give a square, clean cut so the O-ring seats properly: D63, D75 and D90.
The cutter is worth buying rather than improvising. A duct cut at an angle or with a burred edge will not seal against its O-ring, and a slow leak in a buried duct is both invisible and permanent.
Connecting to the manifold
Where the round ducts meet oval duct or a manifold, DucoFlex adapters make the transition, and they too are specified by size and quantity:
Notice what the numbers tell you: three Ø63 runs fit where two Ø75 runs do. That is the size trade-off expressed in hardware, and it is a useful sanity check on a duct layout. How the manifolds themselves are arranged is covered in manifolds, adapters and flow regulators.
Ordering quantities
Duct is sold by the 50 m roll, so the question is how many rolls. Measure each run from the manifold to its terminal along the route it will actually take — around obstructions, not in a straight line — then add an allowance for the drops and for the slack needed to make connections. A run that comes up short cannot be joined mid-floor without creating a buried joint, so it is better to have duct left over.
Order O-rings generously too. They are inexpensive, they come ten to a pack, and a job that stops because the last connection has no seal is an expensive way to save a few pounds.
Before you order, confirm
- The duct diameter specified in your ventilation design, per room
- The number of runs each room needs at that diameter
- Total duct length including vertical drops and routing allowance
- That couplings, O-rings and cutter all match the chosen diameter
- The adapter configuration your manifold arrangement needs
- The floor or ceiling depth available along the whole route, not just at the easy points
Frequently asked questions
Can I mix Ø63 and Ø75 in the same system?
Different rooms can use different diameters where the design calls for it, but each run is one diameter end to end, and the manifold adapters have to suit. Mixing sizes within a single run means a transition fitting and a point of extra resistance, so designs normally avoid it.
Is semi-rigid duct the same as flexible duct?
No. Flexible duct is corrugated and compressible; semi-rigid duct holds its shape, has a smooth bore and is intended to be left in place permanently, including under screed. They behave quite differently in terms of pressure loss and noise.
How does this connect to the DucoBox?
Through a manifold, then larger-diameter duct to the unit itself — Ø125, Ø160 or Ø180 depending on the model. Our guide to the DucoBox range lists the connection size for each unit.
What about noise down the duct?
Correct sizing does most of the work; where more is needed, DUCO lists in-line silencers. See Duco silencers compared.
Next step
Browse the semi-rigid ducting collection for duct, couplings, O-rings and cutters in all three sizes, or read DucoFlex ventilation ducting explained for the system as a whole. If you have a floor plan and room flow rates but no duct schedule, send them over and we will put a parts list together.