Duco Roof and Wall Terminals: Choosing the External Outlet

Short answer: every ventilation system needs two openings to outside — one to draw fresh air in, one to push stale air out. Where those land decides the terminal. A wall gets a wall feed-through; a pitched roof gets either a compact roof terminal or a universal roof tile plus an insulated roof section; a flat roof gets an adhesive flashing plate. Match the diameter to the duct, and on a pitched roof check the pitch range.

DucoFlex Compact roof feed-through Ø160 mm in terracotta for sloping roofs

Wall or roof?

This is usually settled by the building rather than by preference. A wall terminal is simpler, cheaper and easier to reach for cleaning, but it has to land somewhere acceptable on an elevation, and intake and exhaust must be far enough apart that exhausted air is not drawn straight back in. A roof terminal avoids the elevation problem entirely and generally gives cleaner intake air, at the cost of a roof penetration that has to be weathertight for the life of the building.

Whichever you use, the two terminals are not interchangeable in position: an intake sited downwind of an exhaust will short-circuit the system and quietly degrade indoor air quality.

Wall feed-throughs

The DucoFlex wall feed-through is listed for air intake or exhaust through the wall, in black or white, across four diameters:

Diameter Black White
Ø125 mm Black White
Ø160 mm Black White
Ø180 mm Black White
Ø200 mm Black White

Colour is not only cosmetic. On a dark render or brick, black terminals disappear; on white render, white does. Since these are the only visible parts of the ventilation system from outside, it is worth a moment's thought — and worth ordering both terminals in the same colour.

Pitched roofs: two approaches

Compact roof terminals

The compact roof feed-through is a single component for sloping roofs, listed for supply and exhaust, in terracotta or slate grey to suit common roof coverings:

Universal roof tiles plus an insulated section

The alternative is a two-part approach: a universal roof feed-through tile that integrates with the roof covering, and a 1.0 m insulated roof terminal section that carries the duct up through the cold roof space.

The tiles are specified by diameter and by the pitch range they suit:

Tile Diameter Roof pitch
Universal roof tile D160 Ø160 mm 15–55°
Universal roof tile D227 Ø227 mm 15–50°
Universal roof tile D263 Ø263 mm 20–50°

Check the pitch of the actual roof before ordering. The ranges differ between sizes, and the D263 tile starts at 20° rather than 15°, so a shallow roof rules it out.

The matching insulated sections come in three sizes: Ø125 mm, Ø160 mm and Ø180/200 mm, each 1.0 m long.

Insulation on that section matters more than it looks. Warm, humid extract air meeting a cold duct in a loft produces condensation, and condensation in a roof void is a problem that reveals itself slowly and expensively.

Flat roofs

On a flat roof the weathering is done by an aluminium adhesive flashing plate, available in three diameters: Ø160 mm, Ø230 mm and Ø263 mm. The plate is bonded into the roof build-up, so it has to be coordinated with whoever is laying the membrane — this is not a part to buy after the roof is finished.

Choosing: a short path

  1. Where does the duct leave the building? Wall, pitched roof or flat roof.
  2. What diameter is the duct at that point? Usually the unit's connection size, Ø125 to Ø200 mm.
  3. For a pitched roof, what is the pitch? This filters the tile options immediately.
  4. Compact or two-part? Compact is simpler; the tile and insulated section suit a longer run through a cold loft.
  5. What colour or finish? Black or white on walls, terracotta or slate grey on roofs.
  6. Are intake and exhaust far enough apart? Settle this on the drawing, not on site.

Before you order, confirm

  • Duct diameter at the terminal, which may differ from the diameter at the unit
  • Roof pitch, against the tile's stated range
  • Roof covering colour, for terracotta or slate grey
  • Elevation finish, for black or white wall terminals
  • That you are ordering two terminals, intake and exhaust, not one
  • Who is installing it, and whether the roofing programme allows for it

Frequently asked questions

Can intake and exhaust share one terminal?

The items listed here are single-duct terminals, so a standard installation uses two, placed far enough apart to avoid recirculation. Your ventilation designer will set the separation.

Does the terminal need a filter?

No — filtration happens at the unit. Our Duco MVHR filter guide covers which filter set each DucoBox takes.

What size terminal do I need for my unit?

Start from the unit's duct connections: Ø125 mm on the MEV units, Ø160 mm on most MVHR units, Ø180 mm on the Energy Comfort D400. The DucoBox range guide lists them, and the terminal matches whatever diameter the duct has reached by that point.

Will a roof terminal make noise outside?

Exhaust air leaving a terminal carries some fan noise. Where that matters — near a neighbour's window, for instance — an in-line silencer before the terminal is the usual remedy. See Duco silencers compared.

Next step

Browse the roof and wall terminals collection to compare diameters and finishes, or read DucoFlex ventilation ducting explained for how the terminals fit into the wider system. If you know the roof type and pitch but not the part, tell us and we will identify it.